IITJEE CHEMISTRY: Electrochemistry: Nernst Equation & Daniell Cell Visualizer

APEX CLASS • IITJEE Physical Chemistry Lab

Electrochemistry: Nernst Equation & Daniell Cell Visualizer

Master Daniell Cell LOAN Rules, Nernst Equilibrium Shifts, Kohlrausch’s Law, and Faraday’s Electrolysis!

🔬 E°cell = E°cathode(SRP) – E°anode(SRP). Select a Topic:
Zn Zn²⁺(aq) ANODE (-) Cu Cu²⁺(aq) CATHODE (+) Salt Bridge (← Cl⁻ | K⁺ →) 1.1V e⁻ Flow → ← Current I 🏆 Galvanic Cell Mnemonic: “LOAN” • Left | Oxidation | Anode | Negative Terminal • Anode: Zn(s) → Zn²⁺ + 2e⁻ (E° = -0.76 V) • Cathode: Cu²⁺ + 2e⁻ → Cu(s) (E° = +0.34 V) • Standard EMF: E°cell = 0.34 – (-0.76) = +1.10 V • If External Voltage Eext > 1.10 V: Cell reverses and acts as an Electrolytic Cell! 🎯 Cell Notation: Zn(s) | Zn²⁺(aq) || Cu²⁺(aq) | Cu(s). Double line (||) represents the Salt Bridge! 1. Nernst Equation at 298 K (25°C) Ecell = E°cell – (0.0591 / n) log₁₀(Q) • For Daniell Cell (n = 2, Q = [Zn²⁺] / [Cu²⁺]): E = 1.10 – 0.0295 log₁₀( [Zn²⁺] / [Cu²⁺] ) • Increasing [Cu²⁺] (Cathode) → INCREASES Ecell! • At Equilibrium: Ecell = 0 V ⇒ E°cell = (0.0591/n) log Kc 2. Concentration Cells (E°cell = 0 V) • Same electrodes in both half-cells, different concentrations. • Cell Notation: M | M⁺(C₁) || M⁺(C₂) | M Ecell = (0.0591 / n) log₁₀( C₂ / C₁ ) • For the cell to be spontaneous (Ecell > 0): C₂ (Cathode Molarity) MUST BE > C₁ (Anode Molarity)! ⚡ Gas Concentration Cell: Pt | H₂(P₁) | H⁺(C) || H⁺(C) | H₂(P₂) | Pt. Spontaneous only if P₁ > P₂! Adding Standard Potentials (The Latimer Diagram Trap) • E° is an INTENSIVE property (like Temperature). You CANNOT add E°₁ + E°₂ directly! • ΔG° is an EXTENSIVE property. You MUST convert to ΔG°, add, and convert back: E°₃ = (n₁ E°₁ + n₂ E°₂) / n₃ • Example: Fe³⁺ + e⁻ → Fe²⁺ (E°₁, n₁=1) and Fe²⁺ + 2e⁻ → Fe (E°₂, n₂=2) For Fe³⁺ + 3e⁻ → Fe (n₃=3): E°₃ = [ 1(E°₁) + 2(E°₂) ] / 3 🏆 Disproportionation Check: A species undergoes disproportionation if E°right > E°left in its Latimer diagram! 1. H₂-O₂ Fuel Cell (Apollo Program) Hot conc. KOH (aq) H₂(g) O₂(g) H₂O(l) Fuel Cell Reactions & Efficiency • Anode (-): 2H₂ + 4OH⁻ → 4H₂O + 4e⁻ • Cathode (+): O₂ + 2H₂O + 4e⁻ → 4OH⁻ • Net Rxn: 2H₂(g) + O₂(g) → 2H₂O(l) • Thermodynamic Efficiency (η): η = (ΔG / ΔH) × 100% Theoretical η ≈ 83%. Practical is ~60-70%.
Standard Gibbs Energy
ΔG° = -n F E°cell
Max non-expansion work capacity
Nernst Constant at 298K
2.303 RT / F = 0.0591 V
Simplifies base-10 log calculations
Equilibrium Constant (K)
log K = n E°cell / 0.0591
Because at equilibrium Ecell = 0 V!
Fuel Cell vs Batteries
Continuous Reactant Feed
Never “dies” as long as fuel is supplied
🧪 Select a Conductance or Electrolysis Concept:
Λm √C (mol/L)¹/² → ★ Λ°m (Strong: KCl) Strong: Λm = Λ°m – A√C Weak: CH₃COOH (Steep Rise!) Dilution Effects on Conductivity • As Concentration (C) → 0 (Infinite Dilution): 1. Molar Conductivity (Λm) INCREASES. (Due to less inter-ionic attraction for strong, and higher dissociation α for weak). 2. Specific Conductivity (κ) DECREASES! (Fewer ions present per unit volume, cm³). • Formula: Λm = (κ × 1000) / Molarity Kohlrausch’s Law of Independent Migration of Ions At infinite dilution, total molar conductivity is the sum of ionic conductivities. Λ°m(CH₃COOH) = Λ°m(CH₃COONa) + Λ°m(HCl) – Λ°m(NaCl) 1. Degree of Dissociation (α): α = Λm / Λ°m 2. Ostwald’s Dissociation Constant (Ka): Ka = C α² / (1 – α) 🏆 Why it’s useful: Weak electrolytes (like CH₃COOH) cannot have Λ°m found by extrapolation, so we build them using strong electrolytes! Faraday’s First Law W = Z · Q = Z · I · t • W = Mass deposited (g) • Z = Electrochemical Equivalent (E / 96500) • I = Current (Amperes), t = Time (Seconds) W = (M / nf) × (I · t / 96500) Faraday’s Second Law (Cells in Series) Same charge Q passes through all cells. W₁ / E₁ = W₂ / E₂ = Equivalents • The Molar Ratio Trick: For Ag⁺, Cu²⁺, Al³⁺ in series (nf = 1, 2, 3): Moles Ratio = 1/1 : 1/2 : 1/3 = 6 : 3 : 2 Aqueous Electrolysis Rules (Discharge Potential) • Cathode (Reduction): Species with HIGHER Standard Reduction Potential (SRP) wins! Ag⁺ > Cu²⁺ > H⁺ > Na⁺. (So aq. NaCl gives H₂, aq. CuSO₄ gives Cu). • Anode (Oxidation): Species with LOWER Standard Reduction Potential (SRP) wins! I⁻ > Br⁻ > H₂O > F⁻, SO₄²⁻. 🚨 O₂ Overpotential Trap: In aq. NaCl, Cl⁻ oxidizes to Cl₂ instead of H₂O → O₂ due to the high kinetic overvoltage of O₂ on Pt! Active Electrodes: If Anode is Cu or Ag (not Pt), the anode itself oxidizes and dissolves! (e.g., Electrorefining of Copper).
Cell Constant (G*)
G* = l / A
Units: cm⁻¹. Also G* = R × κ
Faraday Constant (F)
96,485 C / mol
Charge of 1 mole of electrons
Electrolysis of Aq NaCl
H₂ at Cathode, Cl₂ at Anode
Solution becomes basic (NaOH left!)
Electrolysis of Aq CuSO₄
Cu at Cathode, O₂ at Anode
Solution becomes acidic (H₂SO₄ left!)
🔥 Two High-Yield Electrochemistry Tips:
1. Nernst Equation Shift: For the Daniell cell, Ecell = 1.10 – 0.0295 log([Zn²⁺]/[Cu²⁺]). Increasing [Cu²⁺] by a factor of 10 increases cell voltage by exactly +0.0295 V!
2. Conductivity Drops: While Molar Conductivity (Λm) increases with dilution, Specific Conductivity (κ) DECREASES because the number of current-carrying ions per unit volume (cm³) decreases!

Leave a Reply